How to assign a spare disk to raid array on a hp server on. I have a an hp dl380 g7 server with a hp smart array p410i raid card. Hp smart array b110i sata raid controller drivers crash hp. Proliant server rebuild array controller issue hpe. Joule has an hp p410 with 1g flash back cache smart array controller. Hp smart array p812 controller onboard expander firmware was updated to version 3. During the install, it asks me to load the driver for the raid, i load the drivers from cp022401 also tried cp020545 and the machine promptly crashes with the hp bios frowny face. Drivers for an hp proliant dl380 g6 running windows server. Configuring arrays on hp smart array controllers reference. I have over 75tb of data and not much extra cash to drum up a proper solution. Good morning, could you support to me in the following issue. I can search it at synology assistant but it shows that i have no hdd as below. However, for different oses, different results show up.
Choose an appropriate driver from the list available on this page. If you dont want to waste time on hunting after the needed driver for your pc, feel free to use a dedicated selfacting installer. Hp smart array p410256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410256mb pcie2 int only manufacturer part number 462862b21. Download free drivers for smart array p410i controller 6. Select the drives that you would like to include in the array. Hp smart array p410 controller hewlett packard enterprise. When i made the raid and other setup with my drives i press esc to get out from the array setup, the z220 reboot and get me in the array setup every time. When the bios displays press any key to view option rom messages press the space bar.
P410i smart array controller sata drive recommendations of known working models. First, i tried replacing one of the spin disk with an ssd drive. The following list of controllers are supported by cciss on distributions based on kernels before 2. Download drivers for hp smart array p410 controller controllers for free. I have 4 drives to setup as a raid 5 configuration but cannot figure out how to do this. Theres no raid setup utility when the system boots. Im trying to install hyperv server 2012 r2 on a bl 460 g7 server but the installation disc doesnt contain the storage drivers and tried p410i server 2012 drivers but the installation doesnt like it. Initially, there was some overlap in the boards which these two drivers support.
Make sure you have physical or console access to the server you wish to create the array on. So i just recently acquired an hp dl360 g7 with an integrated p410i raid controller. The most current 20 version of the p410 quickspecs lists 4tb sata drives as supported. By clicking post your answer, you acknowledge that you have. As expected hp smart array p410i is not supporting raid6 and it is not transparent to operating system i. Search hpe support center drivers for hpe smart array p410. Jul 28, 2017 hp smart array p410i controller raid configuration it blog ixnfo. Solved smart array p400 hardware will not start on. Hdds will be visible to operating system only as logical devices after they are configured in controller. After the smart array device driver hpsa was upgraded to version 3. Can anyone with experience with the pi and sata drives share their experience which models are known to work. Option rom configuration for arrays orcaa simple utility used mainly to configure the first logical drive in a new server before the operating system is loaded. My intention is just to check firmware versions available and compare them to those currently in use. I think there is controller driver missing at the bootloader, may i know where and how to.
Sep 21, 2012 i found on hp drivers for vmware esxi 5. The overall impression regarding building storage system on hp proliant dl380 g7 is miserable. The p410 and p410i are functionally equivalent, as mentioned by kissmyasthma above. Smart array advanced pack saap is a collection of additional and advanced controller features embedded in the firmware of select smart array controllers. I have ran some disk benchmarks on this drives and i get mbps read and only 10mbps write speeds. It appears that the solution was to upgrade the smart array p410i bios. I was hoping the controller would just start rebuilding the.
Retired products sold prior to the november 1, 2015. I have a proliant dl380 g6, and want to know what the maximum hard drive size is for the smart array p410i controller. Pick up a hp p410 raid controller and find the hp raid setup below. Smart array controllers and smart host bus adapters hpe. Installing windows server 2012 r2 on a hp proliant dl20. Retired products sold prior to the november 1, 2015 separation of hewlettpackard company into hewlett packard enterprise company and hp inc. You cant just toss some consumer drives into the server and expect them to work. Here is my experience with hp smartarray controllers with freenas. Windows 10 had no problem finding out the correct drivers for the controller and the lto. Before the update, the bootable drive was the first logical drive created on the controller.
This new driver will support new smart array products going forward, and the cciss driver will eventually be deprecated. There is a builtin tool for managing the smart array controller in hpe proliant servers. Jun 27, 2014 configuring hp smart array p420i io controller for vsan june 27, 2014 july 28, 2015 by pgkeilty, posted in sddc, virtual san, vmware, vsan ive been working with many customers over the last several months and found that many are very familiar with hp hardware and just know how to set things up. Hp smart array p410i controller raid configuration it blog ixnfo. Nov 04, 2018 p410i controller controller will select an aproprate raid level for the number of disks. Apr 25, 2017 find answers to hp dl380 g6 smart array p410i no drives detected from the expert community at experts exchange. You can have monitoring and fan speed problems with random sata disks on that controller. Incompatible device drivers are known to work against the methods that windows 10 follows. Download drivers for smart array p410i controller 6. Make sure you have physical or console access to the server you wish to create the p410i controller on. Hp dl380 g6 smart array p410i no drives detected solutions. Home datacenter compute installing windows 2012 r2 on proliant dl380 g7 without smartstart. Hp smart array p410 raid controller stops working after.
How to change drives on hp smart array p410i solutions. I have a proliant dl g6, and want to know what the maximum hard drive size is for the smart array pi controller. It provides reliability, connectivity, and storage performance for hpe proliant gen8 server blades through its support of the latest sas technology and advanced raid capabilities. The hp smart array p212 is hps entry level pci express pcie serial attached scsi sas raid controller. Greetings, we have a proliant dl380 g6 running windows server 2008 r2 x64. I checked the bios and it shows the raid controller as the primary boot device. Hp protectsguards against that by restricting thirdparty drive use in their servers. Hp smart array p410i controller driver per windows 10 x86. Utilities available for configuring an array to configure an array on an hp smart array controller, three utilities are available. Configuring arrays on hp smart array controllers reference guide. Find answers to hp dl380 g6 smart array p410i no drives detected from the expert community at experts exchange.
Sep 04, 2018 server hardware is a significant investment for any business. The low profile, half height card has 8 ports and utilizes ddr2800 memory. Hp smart array p410 raid controller stops working after falls. It will select only qualified and updated drivers for all hardware parts all alone. To download sci drivers installer, follow this link. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Just make sure youre on the latest smart array firmware and youre good to go. Hp proliant smart array sassata controller driver for windows server 2008 x64 edition. I was sure the proliants used to have a smart array program that you could boot into to configure these discs and also update drivers etc. Find answers to how to change drives on hp smart array p410i from the expert community at experts exchange. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a. The hpe smart array controller provides enterpriseclass storage performance, increased internal scalability with sas expander card, and data protection for hpe proliant rack and tower servers. Hp smart array p410 256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410 256mb pcie2 int only manufacturer part number 462862b21. This has a smartarray p410i controller and seven 2.
Hp smart array p410 controller hp smart array p410 256 2ports int pcie x8 sas controller 462862b21 hp smart array p410 512 bbwc 2ports int pcie x8 sas controller 462864b21 hp smart array p410 512 fbwc 2ports int pcie x8 sas controller 578230b21 hp smart array p410 1g fbwc 2ports int pcie x8 sas controller 572532b21. Since no newer driver is available for windows 10 1709, staying with windows 10 1703 would be the best workaround indeed. Hp proliant smart array sassata controller driver for windows server 2012. Drivers for smart array p410i controller sciologness. Smart array p410i with sata ssd drives unstable server fault. Smart array p410i controller driver for windows 7 32 bit, windows 7 64 bit, windows 10, 8, xp. This enabled an extra option to select the boot device. Drivers installer for smart array p410i controller. A new smart array driver called hpsa has been accepted into the main line linux kernel as of dec 18, 2009, in linux2.
The hpe smart array p721m controller is a pciexpress pcie 3. This configuration guide will walk you through the process of setting up a raid array on your hp p410 p410i. To show all raid array s setup ctrl slot0 pd all show. As amit suggested, i changed boot order but without any success. Did hp ever make a driver for windows 2016 server using a p410i array controller. Now, just having a single configuration that works, i have a way forward, however buying a whole bunch of small old model samsung ssd doesnt seem the ideal solution. I updated the smart array p410i firmware, then in array configuration utility i deleted the array and recreated it, then window 2012 r2 installed ok. Hp sas expander card connected to an hp smart array p410 or hp smart array p410i will require sas expander card firmware version 1. Maximize server storage performance with hpe smart array. We can access it during the the server boot time to configure.
P410i smart array controller sata drive recommendations of. Smart array p410i the raid configuration is stored on all the disks, not the controller. Uploaded on 2242019, downloaded 2371 times, receiving a 94100 rating by 741 users. Hp smart array controllers for hp proliant servers user guide. Im trying to setup a windows 2016 server on a dl360 gen7, that has a p410i array controller. Keep in mind that this is for my home and the data isnt mission. We appreciate the time you took to let us know about the issue you are experiencing with windows 10 fall creators update. You then need to use the hp array configuration utility cli called hpacucli. Need to know if there is a driver for windows 2016. When activated with a registered license key, saap 1. This option allows the driver to attempt to operate on any hp smart array hardware raid controller, even if it is not explicitly known to the driver.
Hp smart array p410 1g fbwc 2ports int pcie x8 sas controller 572532b21 quickspecs hp smart array p410 controller overview da 201 worldwide version 27 december 3, 20 page 2 retired. The driver and utilities can be downloaded from hps offical website. When installing the desktop version, it wouldnt detect any hard drives, whereas the latest debian did but had dchp problems so i tried the raidalternative server version which, after realising that this version is cli only i dont want to use anymore. Smart array p700m smart array p212 smart array p410 smart array p410i. Smart array p440ar, sas to hp 18 g2 tape autoloader, raid1 and 10. Smart array p400 hardware will not start on windows 10. I need to updated the drivers the chipset, display, ipmi interface, base system device, and the nic drivers. Im trying to get work the smart array p410i in my hp z220 sff, but cant pass the initial controller setup.
Raid controllers free delivery possible on eligible purchases. Servers have transformed the way small businesses operate. Access product support documents and manuals, download drivers by operating environment, and view. We purchased an hp ml350 g6 server with a p410i raid controller. My unit has the 256mb cache on it and i would love to get raid 6 enabled. Download hp smart array p410 controller controller drivers. P410i smart array controller sata drive recommendations of known. Raid array performance on an hp proliant ml350 g5 smart array e200i. Im trying to install windows server 2012r2 on a hp dl320 g6 with a smart array b110i sata raid controller. The drives have not failed, but they definitely are not meant to be used with that controller. Very old smart array controllers wouldnt let you move the drives to different bays, but im pretty sure that is supported with the p410. Drivers for an hp proliant dl380 g6 running windows server 2012 r2. Oct 20, 2017 incompatible device drivers are known to work against the methods that windows 10 follows. Configuring hp smart array p420i io controller for vsan.
Vib file is used to update the hpsa driver after the esxi 5. Supported hardware the hpsa driver supports the following smart array boards. Nov 25, 2018 hp smart array p410 controller driver download ill use anything that will keep the fan noise whisper quiet. What you probably need to do is remove the spin drives, then from within acu delete the missing array, once that is done you should be able to move the ssd drives.
Hp smart array p410i controller raid configuration. Most software packages were happy with this including server 2012 standard but hyperv was not. The hp smart array p410i raid controller is not compatible with every ssd. Buy hpe hp smart array p410 8port sas raid controller 512mb ecc ddr2 sdram pci express x8300mbps 2 x minisas sas 300 serial attached scsi internal. Slow drive speeds with hp smart array p410i servethehome. I have attached a single 2tb sata samsung hard drive and created a raid 0 array with the single drive. Use hp sas disks with smart array p410 raid controllers. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement.
20 740 289 1448 1399 820 997 1237 272 381 792 1304 149 1283 440 956 1346 1254 1154 255 1446 895 776 478 1060 1202 363 1465 1417 327 644 883 374 610 756 531 1445 1496 412